Lamp & Electrical Guide

Lamp & Electrical/Ballast Data

Data shown is for typical and compiled from major ballast and lamp suppliers.
Incandescent
Lamp Electrical/Ballast
            Lamp Designation   Wattage (w)        Lamp Envelope            Base      Initial Lumens (lm)     Life (Hrs)     Source   Efficacy(lm/W)*     Input Volts Max Operating Current (Amps)**   Transformer Type 
N 25 A19 Medium 210 2500 8.4 120 0.21 -
N 40 A19 Medium 490 1000 12.3 120 0.33

 -

N 40 T6.5 Intermediate 420 750 10.5 120 0.33  -
N 40 T10 Medium 415 1000 10.4 120 0.33  -
N 60 A19 Medium 840 1000 14.0 120 0.5  -
N 60 T10 Medium 630 1000 10.5 120 0.5  -
N 75 A19 Medium 1170 750 15.6 120 0.63  -
N 100 A19 Medium 1690 750 16.9 120 0.83  -
N 150 A21 Medium 2780 750 18.5 120 1.25  -
N 150 PAR38 Medium 1700 2000 11.3 120/277 1.25/.59 Magnetic for 277V
N 300 PS25 Medium 6200 750 20.7 120 2.5  -
Fluorescent
Lamp Electrical/Ballast
             Lamp Designation    Wattage (w)         Lamp Envelope       Base       Initial Lumens (lm)       Life (Hrs)         Source Efficacy   (lm/W)*       Input Volts Max Operating Current (Amps)**       Ballast Type
QF 13 Quad Tube G24q-1 900 12000 69.2 120/277 .20/.07 Electronic
QF 18 Quad Tube 24q-2 1200 12000 66.7 120/277 .21/.09 Electronic
QF 26 Quad Tube G24q-3 1710 12000 65.8 120/277 .27/.12 Electronic
FS 14 T5   Mini  Bi-pin 1350 30000 96.4 120/277 .21/.08 Electronic
FS 21 T5   Mini  Bi-pin 2100 30000 100.0 120/277 .25/.11 Electronic
FS 28 T5   Mini  Bi-pin 2900 30000 103.6 120/277 .30/.14 Electronic
FS 35 T5   Mini  Bi-pin 3650 30000 104.3 120/277 .34/.15 Electronic
FS 24 T5HO   Mini  Bi-pin 2000 30000 83.3 120/277 .26/.13 Electronic
FS 39 T5HO   Mini  Bi-pin 3500 30000 89.7 120/277 .39/.18 Electronic
FS 54 T5HO   Mini  Bi-pin 5000 30000 92.6 120/277 .58/.25 Electronic
FS 80 T5HO   Mini  Bi-pin 7000 30000 87.5 120/277 .76/.33 Electronic
FCS 22 T5Cir 2GX13 1800 16000 81.8 120/277 .23/.12 Electronic
FCS 40 T5Cir 2GX13 3300 16000 82.5 120/277 .37/.17 Electronic
FO 17 T8   Mini  Bi-pin 1350 20000 79.4 120/277 .17/.08 Electronic
FO 25 T8   Mini  Bi-pin 2150 20000 86.0 120/277 .24/.11 Electronic
FO 32 T8   Mini  Bi-pin 2950 20000 92.2 120/277 .30/.14 Electronic
FO 40 T8   Mini  Bi-pin 3725 20000 93.1 120/277 .37/.16 Electronic
FBO 24 T8 Ulamp   Mini  Bi-pin 1925 20000 80.2 120/277 .18/.08 Electronic
FBO 31 T8 Ulamp   Mini  Bi-pin 2725 20000 87.9 120/277 .23/.10 Electronic
TF 26 Triple Twin Tube

GX24q-3       

1710 12000 65.8 120/277 .26/.12 Electronic
TF 32 Triple Twin Tube  GX24q-3      2200 12000 68.8 120/277 .33/.14 Electronic
TF 42 Triple Twin Tube GX24q-4      3200 12000 76.2 120/277 .45/.20 Electronic
TF 57 Triple Twin Tube GX24q-5    4300 12000 75.4 120/277 .55/.24 Electronic
TF 70 Triple Twin Tube GX24q-6    5200 12000

74.3

120/277 .67/.29 Electronic
LF 13 Twin Tube GX7    820 10000 63.1 120/277 .14/.06 Electronic
F 9 Twin Tube G23 600 10000 66.7 120/277 .10/.17 (npf) Magnetic
F 18 Twin Long Tube 2G11 1250 20000 69.4 120/277 .19/.08 Electronic
F 27 Twin Long Tube 2G11 1800 12000 66.7 120/277 .25/.12 Electronic
F 39 Twin Long Tube 2G11 2850 12000 73.1 120/277 .38/.17 Electronic
F 40 Twin Long Tube 2G11 3150 20000 78.8 120/277 .42/.19 Electronic
F 50 Twin Long Tube 2G11 4000 14000 80.0 120/277 .53/.22 Electronic
F 55 Twin Long Tube 2G11 4800 10000 87.3 120/277 .50/.22 Electronic
F 36 DuluxF 2G10 2800 10000 77.8 120/277 .28/.14 Electronic
F 21 2D GR10q-4 1350 10000 64.3 120/277 .31/.08 (npf) Electronic
F 28 2D GR10q-4 2050 10000 73.2 120/277 .45/.13 (npf) Electronic
F 38 2D GR10q-4 2850 10000 75.0 120/277 .56/.15 (npf) Electronic
Data shown is typical and compiled from major LED suppliers as of publication date.
Solid State Lighting (LED)
Lamp
Lamp Designation     Color  Source Efficacy (lm/w)*   Life (Hrs)***
LEDAMB Amber 42 50000 (L70)
LEDCWT

Cool White (Nominal 4100K)

55

 50000 (L70)

LEDGRN Green 44  50000 (L70)
LEDNWT

Neutral White (Nominal 3500K)

48  50000 (L70)
LEDRED Red 44  50000 (L70)
Solid State Lighting (LED) Flood Module
Lamp
Lamp Designation     Wattage (w) Envelope  Radiance Angle Luminous Intensity (cd)   Color Current (ma)
LED12FL16 12 FL16 250 700 3300K 500
* To allow comparison with other lamp data shown, this is source efficacy at expected operating temperature.  Ballasts, drivers and optics will reduce this rating when inside a lighting fixture.  Ballasts, drivers and optical systems may have combined losses of 15-30%.
**  Unless otherwise noted, Visa Lighting supplies High Power Ballasts and Drivers with a ballast factor between .85 and 1.15.  Operating current values with typically be less than listed.
*** Life expectancy at stablized fixture operating temperature.  "L70" is the point in time when the LED emitters reach 70% of their initial rated lumens.
Tungsten Halogen
Lamp Electrical/Ballast
             Lamp Designation   Wattage (w)         Lamp Envelope     Base       Initial Lumens (lm)      Life (Hrs) Source    Efficacy     (lm/W)*      Input Volts Max Operating Current (Amps)**   Transformer Type
T 20 MR16 GX5.3 500 2000 25.0 120/277 .18/.08 Electronic
T 37 MR16 GX5.3 875 2000 25.0 120/277 .27/.15 Electronic
T 50 MR16 GX5.3  1250 2000 25.0 120/277 .46/.20 Electronic
T 50 PAR20

Medium

570 2500 11.4 120/277 .46/.20 Electronic
T 50 PAR30

Medium

630 3000 12.6 120/277 .42/.19 Magnetic for 277V
T 75 PAR30

Medium

1030 3000 13.7 120 0.63 -
T 250 PAR38

Medium

3600 2880 14.4 120/277 2.08/.99 Magnetic for 277V
T 100 T4 Minican 1600 2000 16.0 120 0.83

-

T 150 T4 Minican 2800 2000 18.7 120 1.25 -
T 250 T4 Minican 5000 2000 20.0 120 2.08 -
High Intensity Discharge (HID)
Lamp Electrical/Ballast
            Lamp Designation    Wattage (w)        Lamp Envelope       Base          ANSI      Initial Lumens (lm)      Life (Hrs)     Source    Efficacy     (lm/W)*      Input Volts Max Operating Current (Amps)**   Transformer Type
PH 50 ED17  Medium M110 3000 10000 60.0 120/277 .47/.20 Electronic
PH 50 ED17  Medium M110 3000 10000 60.0 120/277 .65/.30 Magnetic
PH 70 ED17  Medium M98 5300 12000 75.7 120/277 .68/.31 Electronic
PH 70 ED17

 Medium

M98 5300 12000 75.7

120/277

.85/.37 Magnetic
PH 100 ED17

 Medium

M90 8500 15000 85.0 120/277 .93/.40 Electronic
PH 100 ED17

 Medium

M90 8500 15000 85.0 120/277 1.15/.50 Magnetic
PH 150 ED17

 Medium

M102/M142 12600 15000 84.0 120/277 1.39/.62 Electronic
PH 150 ED17  Medium M102/M142 12600 15000 84.0 120/277 1.60/.70

Magnetic

PH 175 ED17  Medium M137/M152 16500 15000 94.3 120/277 1.70/.70 Electronic
PH 175 ED17  Medium M137/M152 16500 15000 94.3 120/277 1.75/.75 Magnetic
PH 250 ED28 Mogul M138/M153 21500 15000 86.0 120/277 2.75/1.20 Electronic
PH 320 ED28 Mogul M138/M154 33000 20000 103.1 120/277 3.35/1.46 Magnetic
PH 400 ED28 Mogul M138/M155 42000 20000 105.0 120/277 4.10/1.80 Magnetic
H 39 PAR20 Medium M130 21000 10000 53.8 120/277 .53/.24 Magnetic
H 70 PAR30 Medium M98/M139 4700 13000 67.1 120/277 .81/.35 Magnetic
H 150 PAR38 Medium M102/M142 9100 12000 60.7 120/277 1.60/.70 Magnetic
H 175 ED17 Medium M57 12900 10000 73.7 120/277 1.90/.80 Magnetic
H 250 ED28 Mogul M58 18000 10000 72.0 120/277 2.50/1.10 Magnetic
H 400 ED28 Mogul M59 35000 15000 87.5 120/277 4/1.75 Magnetic
H 250 ET18/T15 Mogul M58 22000 17500 88.0 120/277 2.50/1.10 Magnetic
CH 20 T4 G8.5 M156 1700 9000 85.0 120/277 .22/.11 Electronic
CH 39 T4 G8.5 M130 3150 12000 80.8 120/277 .38/.17 Electronic
CH 39 T4 G8.5 M130 3150 12000 80.8 120/277 .53/.24 Magnetic
CH 39 T4 G12 M130 3150 12000 80.8 120/277 .38/.17 Electronic
CH 39 T4 G12 M130 3150 12000 80.8 120/277 .53/.24 Magnetic
CH 70 T4 G8.5 M139 6200 9000 88.6 120/277 .68/.31 Electronic
CH 70 T4 G8.5 M139 6200 9000 88.6 120/277 .85/.37 Magnetic
CH 70 T6 G12 M139 6600 12000 94.3 120/277 .68/.31 Electronic
CH 70 T6 G12 M139 6600 12000 94.3 120/277 .85/.37 Magnetic
CH 150 T6 G12 M102/M142  140 12000 93.3 120/277 1.39/.62 Electronic
CH 150 T6 G12 M102/M142   12000 93.3 120/277 1.60/.70 Magnetic
PH = pulse start     H (39, 70, 150) = pulse start      H (175, 250, 400, 250) = probe start      CH = ceramic 
* To allow comparison with other lamp data shown, this is source efficacy at expected operating temperature.  Ballasts, drivers and optics will reduce this rating when inside a lighting fixture.  Ballasts, drivers and optical systems may have combined losses of 15-30%.
**  Unless otherwise noted, Visa Lighting supplies High Power Ballasts and Drivers with a ballast factor between .85 and 1.15.  Operating current values with typically be less than listed.